Product Identification

Product ID:LN 3365-24 PART A, T-1365
MSDS Date:03/21/1991
FSC:8040
NIIN:00N038779
MSDS Number: BRHLS

Responsible Party
EMERSON & CUMING INC
77 DRAGON CT
WOBURN, MA 01888
US

Emergency Phone: 617-935-4850;617-938-3630

Info Phone: 617-828-3300

Preparer: ANIELLO MURANO

Cage: DO244

Contractor
EMERSON & CUMING INC DIV/W R GRACE CO
AUOBURN, MA 01888 US

Telephone: (617) 935-4850 OR (617) 938-8630

Cage: DO244

Ingredients

PVNT RUNOFF FROM ENTERING WATERWAYS. TRANSFER

RTECS: 9999999ZZ


EPOXY RESINS

Fraction By Weight: 60-80%


GLASS MICROBALLOONS

Fraction By Weight: 10-30%


ORGANOPHOSPHOROUS FLAME RETARDANT

Fraction By Weight: <5%


ADDITIVE

CAS: 24937-78-8

Fraction By Weight: <5%


MINERAL FILLER

Fraction By Weight: <100%


PIGMENT

Fraction By Weight: <1%


INDUCE VOMITING. NEVER GIVE ANYTHING BY MOUTH TO

RTECS: 9999999ZZ


DURING COMBUST. CHEM NATURE & QTY OF

RTECS: 9999999ZZ


IN SOME MICROBIAL TESTS, BUT HAS FAILED TO

RTECS: 9999999ZZ


WERE OBSERVED IN CULTURED RAT LIVER CELLS.

RTECS: 9999999ZZ


ACCESS TO IMMED SPILL AREA. SHUT OFF SOURCE OF

RTECS: 9999999ZZ


AVAIL EXHST VENT SYS IN AREA. DIKE AREA TO CONTAIN

RTECS: 9999999ZZ


COLLECT SPILLED MATL FOR SALVAGE/DISP. APPLY ABSORB

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYE: CONTAINS MATLS WHICH MAY
CAUSE SEV BUT REVERSIBLE EYE IRRIT. SKIN:CONTAINS MATLS WHICH CAUSE
MOD SKIN IRRIT. PRLNGD/RPTD EXPOS TO LIQ MAY EXERT DEFAT/DRYING
ACTION ON SKIN,POSS RSLTG IN DE RM.PROD MAY CAUSE SKIN
SENSIT/ALLERGIC SKIN RXNS WHICH MAY BE SEV IN CERTAIN INDIV; SYMPS
INCL RASH, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:ITCHING, HIVES, SWELLING OF
EXTREMITIES. INHAL:HEATING CAN GEN VAPS THAT MAY CAUSE RESP IRRIT,
NAUS & HDCH.INHAL HAZ AT ROOM TEMP IS UNLIKELY, DUE TO LOW
VOLATILITY OF PROD. INGEST: HARMFUL I F SWALLOWED. CHRONIC:
ALTHOUGH SIGNIFICANCE IS UNKNOWN, DGEBA EPOXY RESIN IN PROD HAS
BEEN SHOWN TO BE MUTAGENIC (ING 9)
Medical Cond Aggravated by Exposure:EXPOSURE MAY AGGRAVATE PREEXISTING
SKIN AND/OR EYE DISORDERS.

First Aid

First Aid:EYE: FLUSH THORO W/WATER FOR AT LST 15 MINS WHILE HOLDING
EYELIDS OPEN. GET MED ATTN. SKIN: REMOVE ANY CONTAMD CLTHG & FLUSH
AFFECTED AREA THORO W/PLENTY OF WATER. FOLLOW BY WASHING W/SOAP &
WATER. GE T MED ATTN IF IRRIT PERSISTS. DO NOT REUSE CONTAMD CLTHG
UNTIL PROPERLY CLEANED. INHAL: REMOVE TO FRESH AIR. PROVIDE OXYGEN
IF BRTHG IS DFCLT. GIVE ARTF RESP IF NOT BRTHG. GET IMMED MED ATTN.
(SUPDAT)

Fire Fighting

Flash Point Method:SCC
Flash Point:>200F,>93C
Extinguishing Media:USE CARBON DIOXIDE, DRY CHEMICAL, FOAM, WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. COOL EXPOS CNTNRS W/WATER TO PVNT PRESS BUILDUP. IF LRG QTYS OF
MATL ARE INVOLVED, EVAC AREA & (SUPDAT)
Unusual Fire/Explosion Hazard:DECOMPOSITION AND COMBUSTION PRODUCTS MAY
BE TOXIC. CLOSED CONTAINERS MAY VIOLENTLY RUPTURE UNDER FIRE
CONDITIONS.

Accidental Release

Spill Release Procedures:SML SPILLS: ACTIVATE AVAIL EXHST VENT EQUIP IN
IMMED SPILL AREA. WIPE UP/ABSORB SPILLED MATL W/VERMICULITE/OTHER
SIMILAR MATL. WASH AREA W/SOAPY WATER TO REMOVE RESIDUE. COLLECT
ABSORB MATL & WATER RI NSES IN APPROP CNTNRS. LRG SPILLS: LIMIT
(ING 11)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN COOL, DRY LOCATION WITH
ADEQUATE VENTILATION. KEEP CONTAINER TIGHTLY SEALED WHEN NOT IN
USE. KEEP AWAY FROM OPEN FLAMES AND HEAT SOURCES.
Other Precautions:CONSULT PRODUCT TECHNICAL BULLETIN FOR DETAILED
STORAGE INFORMATION.

Exposure Controls

Respiratory Protection:USE AN APPROPRIATE, NIOSH/MSHA APPROVED PROPERLY
FITTED RESPIRATOR IF SYMPTOMS OF EXPOSURE APPEAR. THE TYPE OF RESP
PROT SELECTED WILL DEPEND ON CONDITIONS OF USE. OBSERVE OSHA
REGULATIONS FOR RESPIRA TORY PROTECTION 29 CFR 1910.1349.
Ventilation:PROVIDE EFT MECH EXHST VENT TO DRAW VAPS, MISTS/FUMES
GENERATED DURING PROCESSING AWAY FROM WORKER & PREVENT (SUPDAT)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEM WORK GOG &/FULL LGTH FSHLD
Other Protective Equipment:A PROPER CHEM-RESISTANT APRON & IMPERVIOUS
CLTHG TO ELIM POTNTL FOR SKIN CONT & CONTAM OF CLTHG. EMER EYE WASH
(SUPDAT)
Work Hygienic Practices:NORMAL WORK CLTHG SHOULD BE WASHED BEFORE
REUSE. WASH HANDS & FACE THORO AFTER HNDLG PROD & BEFORE EATING,
(SUPDAT)
Supplemental Safety and Health
FIRE FIGHT PROC:FIGHT FIRE FROM SAFE DISTANCE. HYGIENE PRACT:
DRINKING/SMOKING. OTHER PROT EQUIP: FACILITIES & SAFETY SHOWER MUST
BE AVAIL. VENT:ROUTINE INHAL. THIS IS NEC ESPEC DURING ELEVATED
TEMP P ROCESSING. VENT MUST BE SUFF TO PVNT RESP IRRIT AS VAPS CAN
BE SEV RESP IRRIT. FIRST AID PROC:INGEST: DO NOT (ING 7)

Chemical Properties

Vapor Pres:<1 @ 25C
Vapor Density:HVR/AIR
Spec Gravity:<0.7 (H*20=1)
Solubility in Water:NIL
Appearance and Odor:BLACK, MILD ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS, ACIDS, BASES; UNCNTRLD MIXING WITH AMINES,
ANHYDRIDES, MERCAPTANS MAY CAUSE HAZARDOUS POLYMERIZATION.
Stability Condition to Avoid:STOR IN OPEN CNTNRS,EXPOS TO OPEN
FLAME/UNCNTRLD EXPOS TO HEAT,UNCNTRLD MIX W/CURING AGENTS/EXPOS TO
INCOMPAT SUBSTANCES
Hazardous Decomposition Products:CARBON MONOXIDE,CARBON DIOXIDE,
ALDEHYDES,ACIDS, HYDROGEN BROMIDE, BROMINE & OTHER ORG SUBSTANCES
MAY BE FORMED (ING 8)
Conditions to Avoid Polymerization:AVOID CONTACT W/STRONG
OXIDIZERS,ACIDS,BASES,AMINES,ANHYDRIDES AND MERCAPTANS.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH CURRENT FEDERAL,
STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.